Schneider Electric
ريلاي حماية للمحركات ودرجة حرارة الملفات Motor voltage and temperature control relay
- SKU:
- RM35TM50MW
- الشحن والتسليم:
- الشحن خلال الفترة من 2-3 ايام عمل بخلاف ايام الاحد والعطلات الرسمية
- تغليف كهدية
- اختيارات متوفرة
الوصف
range of product |
Zelio Control
|
|
---|---|---|
product or component type |
Modular measurement and control relays
|
|
relay type |
Motor temperature control relay
|
|
product specific application |
For 3-phase supply
|
|
relay name |
RM35TM
|
|
relay monitored parameters |
Phase sequence
Motor temperature via PTC probe Phase failure detection |
|
time delay |
Fixed 0.3 s
|
|
switching capacity in VA |
1250 VA
|
|
measurement range |
208...480 V voltage AC
0...20 Ohm short-circuit detection |
reset time |
10000 ms output
|
|
---|---|---|
maximum switching voltage |
250 V AC
250 V DC |
|
minimum switching current |
10 mA at 5 V DC
|
|
maximum switching current |
5 A AC
5 A DC |
|
supply voltage limits |
20.4…264 V AC
20.4…264 V DC |
|
power consumption in VA |
0…4 VA at 24...240 V AC
|
|
power consumption |
0.5 W DC
|
|
control circuit frequency |
50...60 Hz +/- 10 %
|
|
resistance across terminals |
602 mOhm
|
|
output contacts |
2 NO
|
|
nominal output current |
5 A
|
|
measurement voltage limits |
176…528 V AC
|
|
delay at power up |
500 ms
|
|
voltage range |
176...528 V
|
|
response time |
> 50 ms (input Y1 (contact Y1-T1) and push-button)
|
|
[Uc] control circuit voltage |
<= 3.6 V of temperature control circuit (T1-T2 terminals open)
|
|
short-circuit current |
0.007 A temperature sensing circuit (T1-T2 terminals short circuited)
|
|
maximum resistance |
1500 Ohm for temperature sensor at 20 °C
|
|
tripping threshold |
3100 Ohm +/- 10 % for temperature control circuit
|
|
reset threshold |
1650 Ohm +/- 10 % for temperature control circuit
|
|
marking |
CE
|
|
overvoltage category |
III conforming to IEC 60664-1
|
|
insulation resistance |
> 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5
> 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1 > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5 > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1 > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5 > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1 |
|
[Ui] rated insulation voltage |
400 V conforming to IEC 60664-1
|
|
supply frequency |
50/60 Hz +/- 10 %
|
|
operating position |
Any position without derating
|
|
connections - terminals |
Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end |
|
tightening torque |
0.6…1 N.m conforming to IEC 60947-1
|
|
housing material |
Self-extinguishing plastic
|
|
local signalling |
LED (green) for power ON
LED (yellow) for phase of relay (R2) LED (yellow) for temperature of relay (R1) |
|
mounting support |
35 mm symmetrical DIN rail conforming to EN/IEC 60715
|
|
electrical durability |
10000 cycles
|
|
mechanical durability |
30000000 cycles
|
|
operating rate |
<= 360 operations/hour full load
|
|
utilisation category |
AC-12 conforming to IEC 60947-5-1
AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 |
|
width |
35 mm
|
|
net weight |
0.13 kg
|
immunity to microbreaks |
20 ms at 20.4 V
|
|
---|---|---|
electromagnetic compatibility |
Emission standard for industrial environments conforming to EN/IEC 61000-6-4
Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3 Immunity for industrial environments conforming to EN/IEC 61000-6-2 |
|
standards |
EN/IEC 60255-6
IEC 60034-11-2 |
|
product certifications |
GL
UL GOST C-Tick CSA |
|
directives |
73/23/EEC - low voltage directive
89/336/EEC - electromagnetic compatibility |
|
ambient air temperature for storage |
-40…70 °C
|
|
ambient air temperature for operation |
-20…50 °C
|
|
relative humidity |
95 % at 55 °C conforming to IEC 60068-2-30
|
|
vibration resistance |
0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6
1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1 |
|
shock resistance |
15 gn for 11 ms conforming to IEC 60255-21-1
|
|
IP degree of protection |
IP20 (terminals) conforming to IEC 60529
IP30 (casing) conforming to IEC 60529 |
|
pollution degree |
3 conforming to IEC 60664-1
|
|
dielectric test voltage |
2 kV, 1 min AC 50 Hz
|
|
non-dissipating shock wave |
4 kV
|
Unit Type of Package 1 |
PCE
|
|
---|---|---|
Number of Units in Package 1 |
1
|
|
Package 1 Weight |
130 g
|
|
Package 1 Height |
4.5 cm
|
|
Package 1 width |
7.8 cm
|
|
Package 1 Length |
9.6 cm
|
|
Unit Type of Package 2 |
S03
|
|
Number of Units in Package 2 |
48
|
|
Package 2 Weight |
6.918 kg
|
|
Package 2 Height |
30 cm
|
|
Package 2 width |
30 cm
|
|
Package 2 Length |
40 cm
|