Schneider Electric
ريلاى حماية غرف المصاعد Temperature control relay for lifts application
- SKU:
- RM35ATR5MW
- الشحن والتسليم:
- الشحن خلال الفترة من 2-3 ايام عمل بخلاف ايام الاحد والعطلات الرسمية
- تغليف كهدية
- اختيارات متوفرة
الوصف
range of product |
Zelio Control
|
|
---|---|---|
product or component type |
Modular measurement and control relays
|
|
relay type |
Temperature control relays
|
|
product specific application |
For elevator machine rooms and 3-phase supplies
|
|
relay name |
RM35AT
|
|
relay monitored parameters |
Overtemperature: 34...46°C
Undertemperature: -1...11°C |
|
time delay range |
0.1...10 s adjustable delay (tolerance: 0...10 % of the full scale value)
|
|
switching capacity in VA |
1250 VA
|
|
minimum switching current |
10 mA at 5 V DC
|
|
maximum power consumption in VA |
3.5 VA AC
|
|
utilisation category |
AC-12 conforming to IEC 60947-5-1
AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 DC-14 conforming to IEC 60947-5-1 |
reset time |
8 s
|
|
---|---|---|
maximum switching voltage |
250 V AC/DC
|
|
[Us] rated supply voltage |
24...240 V AC/DC
|
|
[Us] rated supply voltage |
24...240 V AC/DC
|
|
supply voltage limits |
20.4…264 V AC
21.6…264 V DC |
|
maximum power consumption in W |
0.6 W DC
|
|
resistance across terminals |
1.33 kOhm at temperature
|
|
width |
35 mm
|
|
output contacts |
2 NO
|
|
contacts material |
Cadmium free
|
|
nominal output current |
5 A
|
|
delay at power up |
0.2 s
|
|
measurement accuracy |
+/- 2 °C
|
|
response time |
<= 3.5 s + Tt (in case of temperature fault)
<= 3.5 s (on disappearance of fault) |
|
temperature probe type |
Pt 100 - 3-wire
|
|
installed device |
Pt 100 probe cable length <= 10 m
|
|
marking |
CE : EMC 89/336/EEC
CE : 73/23/EEC |
|
overvoltage category |
III conforming to IEC 60664-1
|
|
insulation resistance |
> 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5
> 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1 > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5 > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1 > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5 > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1 |
|
[Ui] rated insulation voltage |
250 V conforming to IEC 60664-1
|
|
operating voltage tolerance |
- 10 % + 10 % Un DC
- 15 % + 10 % Un AC |
|
supply frequency |
50/60 Hz +/- 10 %
|
|
insulation |
Galvanic insulation between supply and measurement
|
|
operating position |
Any position without derating
|
|
connections - terminals |
Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end |
|
tightening torque |
0.6…1 N.m conforming to IEC 60947-1
|
|
housing material |
Self-extinguishing plastic
|
|
local signalling |
1 LED green for power ON
1 LED yellow for correct temperature (high R1) 1 LED yellow for correct temperature (low R2) |
|
mounting support |
35 mm symmetrical DIN rail conforming to EN/IEC 60715
|
|
electrical durability |
100000 cycles
|
|
mechanical durability |
30000000 cycles
|
|
operating rate |
<= 360 operations/hour full load
|
immunity to microbreaks |
10 ms
|
|
---|---|---|
electromagnetic compatibility |
Emission standard for industrial environments conforming to EN/IEC 61000-6-4
Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3 Immunity for industrial environments conforming to NF EN/IEC 61000-6-2 |
|
standards |
IEC 60255-6
NF EN 60255-6 |
|
product certifications |
GL
GOST C-Tick CSA UL |
|
ambient air temperature for storage |
-40…70 °C
|
|
ambient air temperature for operation |
-20…50 °C
|
|
vibration resistance |
0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1
1 gn (f= 57.6…150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1 |
|
shock resistance |
15 gn for 11 ms conforming to IEC 60255-21-1
|
|
IP degree of protection |
IP20 (terminals) conforming to IEC 60529
IP30 (casing) conforming to IEC 60529 |
|
pollution degree |
3 conforming to IEC 60664-1
|
|
dielectric test voltage |
2 kV, 1 min AC 50 Hz
|
|
non-dissipating shock wave |
4 kV
|
Package 1 Weight |
0.135 kg
|
|
---|---|---|
Package 1 Height |
0.800 dm
|
|
Package 1 width |
0.460 dm
|
|
Package 1 Length |
0.970 dm
|
Sustainable offer status |
Green Premium product
|
|
---|---|---|
REACh Regulation | ||
EU RoHS Directive |
Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration |
|
Mercury free |
Yes
|
|
RoHS exemption information | ||
China RoHS Regulation | ||
Environmental Disclosure | ||
Circularity Profile | ||
WEEE |
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
|