Fluke
Fluke 117 Electrician's Multimeter with Non-Contact Voltage
- SKU:
- 2538815
- Availability:
- الشحن خلال الفترة من 2-3 ايام عمل بخلاف ايام الاحد والعطلات الرسمية
- التغليف
- متاح اختيارات تغليف
الوصف
Key features
- Compact, true-rms digital multimeter for electricians
- Includes multimeter, 4mm silicone test leads, holster and manual
- Integrated non-contact voltage detection keeps you safe
- Prevent false readings from ghost voltage with selectable low-impedance mode
Product overview: Fluke 117 Electrician's Multimeter with Non-Contact Voltage
Fluke 117: Compact digital multimeter designed for electricians
The Fluke 117 Electricians Multimeter is a compact, CAT III 600 V, True-rms meter that includes an easy-to-use interface with a bright backlight for darker worksites. It saves you time and enables you to move from job to job more quickly. With a quick turn of the dial you can get measurements for:
- Resistance
- Continuity
- Frequency
- Capacitance
- Min/Max/Average
For the everyday
A digital multimeter designed to be hauled everywhere with you, part of your everyday tools. The 117 is built for demanding applications like:
- Commercial buildings
- Hospitals
- Schools
Non-contact voltage detection
Keep yourself safer with integrated VoltAlert™ technology. Fast, go/no go non-contact voltage detection built into your multimeter saves you from having to carry around or find an extra tool to get the work started.
Automatic AC/DC selection
Set the dial and get your measurement quickly with AutoVolt. This automatic AC/DC voltage selector makes it easier for you to get the measurement you need and move on quicker.
Frequently asked questions
What is the difference between the Fluke 115 and the Fluke 117?
While similar, the Fluke 115 and the Fluke 117 meters are designed for slightly different purposes. The Fluke 115 is a compact true-rms digital multimeter that’s great for field service. The Fluke 117 is a designed specifically for electricians. With a quick turn of the dial both units provide measurements for:
- Resistance
- Continuity
- Frequency
- Capacitance
- Min/Max/Average
The Fluke 117 offers non-contact voltage detection and has a selectable low-impedance mode to prevent false readings from ghost voltage. The 117 also features automatic selection of AC or DC voltage, depending on what was detected.
Does the Fluke 117 read milliamps?
The Fluke 117 Electrician’s Multimeter includes a 10 amp current range for making both AC or DC current measurements. The maximum resolution is 1 milliamp.
Specifications: Fluke 117 Electrician's Multimeter with Non-Contact Voltage
Specifications | ||
Maximum voltage between any terminal and earth ground | 600 V | |
Safety | IEC 61010-1: Pollution Degree 2 IEC 61010-2-033: CAT III 600V |
|
Fuse for A input | 11 A, 1000 V FAST Fuse (Fluke PN 803293) | |
Display | Digital: 6,000 counts, updates 4 per second | |
Bar graph | 33 segments, updates 32 per second | |
Operating temperature | -10°C to +50°C | |
Storage temperature | -40°C to +60°C | |
Battery type | 9 volt Alkaline, IEC 6LR61 | |
Battery life | 400 hours typical, without backlight | |
Accuracy Specifications | ||
DC millivolts | Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
DC volts | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
Auto volts | Range/resolution | 600.0 V / 0.1 V |
Accuracy | 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz) |
|
AC millivolts¹ True RMS | Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
AC volts¹ True RMS | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
Continuity | Range/resolution | 600 Ω / 1 Ω |
Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer. |
|
Ohms | Range/resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ |
Accuracy | 0.9% + 1 | |
Range/resolution | 40.00 MΩ / 0.01 MΩ | |
Accuracy | 5% + 2 | |
Diode test | Range/resolution | 2.00 V / 0.001 V |
Accuracy | 0.9% + 2 | |
Capacitance | Range/resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF |
Accuracy | 1.9% + 2 | |
Range/resolution | > 1000 μF | |
Accuracy | 5% + 20% | |
Lo-Z capacitance | Range | 1 nF to 500 μF |
Accuracy | 10% + 2 typical | |
AC amps True RMS (45 Hz to 500 Hz) | Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
Accuracy | 1.5% + 3 20 A continuous overload for 30 seconds max |
|
DC amps | Range/resolution |
6.000 A / 0.001 A 10.00 A / 0.01 A |
Accuracy | 1.0% + 3 20 A continuous overload for 30 seconds max |
|
Hz (V or A input)² | Range/resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 Hz 50.00 kHz / 0.01 Hz |
Accuracy | 0.1% + 2 | |
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. |
||
Mechanical and General Specifications | ||
Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | |
Weight | 550 g |