Schneider Electric
ريلاى حماية للطلمبات
- SKU:
- RM35BA10
- الشحن والتسليم:
- الشحن خلال الفترة من 2-3 ايام عمل بخلاف ايام الاحد والعطلات الرسمية
- تغليف كهدية
- اختيارات متوفرة
الوصف
range of product |
Zelio Control
|
|
---|---|---|
product or component type |
Modular measurement and control relays
|
|
relay type |
Pump control relays
|
|
product specific application |
For 3-phase and single-phase pump
|
|
relay name |
RM35BA
|
|
relay monitored parameters |
Overcurrent and undercurrent control
Phase sequence on 3-phase supply Phase failure on 3-phase supply |
|
time delay type |
Adjustable 1...60 s, +/- 10 % Ti on energisation
Fixed 0.3 s reset on terminal Y2 Adjustable 0.1...10 s, +/- 10 % Tt on crossing the threshold |
|
switching capacity in VA |
1250 VA
|
|
minimum switching current |
10 mA at 5 V DC
|
|
maximum switching current |
5 A AC/DC
|
|
maximum power consumption in VA |
5 VA AC
|
|
measurement range |
1...10 A AC
|
|
utilisation category |
AC-12 conforming to IEC 60947-5-1
AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 |
reset time |
2000 ms
|
|
---|---|---|
maximum switching voltage |
250 V AC/DC
|
|
[Un] rated nominal voltage |
208...480 V AC 3 phases
230 V AC single phase |
|
[Un] rated nominal voltage |
208...480 V AC 3 phases
230 V AC 1 phase |
|
supply voltage limits |
183…528 V AC
|
|
operating voltage tolerance |
- 15 % + 10 % Un
|
|
resistance across terminals |
0.01 Ohm at E1-L2 terminals
|
|
width |
35 mm
|
|
output contacts |
1 C/O
|
|
nominal output current |
5 A
|
|
maximum measuring cycle |
140 ms as true rms value
|
|
delay at power up |
0.5 s
|
|
hysteresis |
5 % of threshold
|
|
measurement accuracy |
+/- 10 % of the full scale value
|
|
repeat accuracy |
+/- 1 % for input and measurement circuit
+/- 1 % for time delay |
|
measurement error |
1 % by volt over the whole range
+/- 0.05 %/°C |
|
response time |
< 300 ms (in the event of a fault)
|
|
overload input current |
11 A permanent at 25 °C E1-L2 terminals
50 A non repetitive < 1 s at 25 °C E1-L2 terminals |
|
marking |
CE : EMC 89/336/EEC
CE : 73/23/EEC |
|
overvoltage category |
III conforming to IEC 60664-1
|
|
insulation resistance |
> 500 MOhm at 500 V DC between supply and relay output conforming to 60255-5
> 500 MOhm at 500 V DC between measurement and relay output conforming to 60664-1 > 1 MOhm at 500 V DC between supply and measurement conforming to 60255-5 > 500 MOhm at 500 V DC between supply and relay output conforming to 60664-1 > 500 MOhm at 500 V DC between measurement and relay output conforming to 60255-5 > 1 MOhm at 500 V DC between supply and measurement conforming to 60664-1 |
|
[Ui] rated insulation voltage |
400 V conforming to IEC 60664-1
|
|
supply frequency |
50/60 Hz +/- 10 %
|
|
operating position |
Any position
|
|
connections - terminals |
Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end |
|
tightening torque |
0.6…1 N.m conforming to IEC 60947-1
|
|
housing material |
Self-extinguishing plastic
|
|
status LED |
1 LED green for power ON
1 LED yellow for fault 1 LED yellow for relay ON |
|
mounting support |
35 mm symmetrical DIN rail conforming to EN/IEC 60715
|
|
electrical durability |
100000 cycles
|
|
mechanical durability |
30000000 cycles
|
|
operating rate |
<= 360 operations/hour full load
|
immunity to microbreaks |
500 ms
|
|
---|---|---|
electromagnetic compatibility |
Emission standard for industrial environments conforming to EN/IEC 61000-6-4
Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3 Immunity for industrial environments conforming to NF EN/IEC 61000-6-2 |
|
standards |
EN/IEC 60255-6
|
|
product certifications |
C-Tick
CSA GOST UL GL |
|
ambient air temperature for storage |
-40…70 °C
|
|
ambient air temperature for operation |
-20…50 °C
|
|
relative humidity |
95 % at 55 °C conforming to IEC 60068-2-30
|
|
vibration resistance |
0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1
1 gn (f= 57.6…150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1 |
|
shock resistance |
15 gn for 11 ms conforming to IEC 60255-21-1
|
|
IP degree of protection |
IP20 (terminals) conforming to IEC 60529
IP30 (casing) conforming to IEC 60529 |
|
pollution degree |
3 conforming to IEC 60664-1
|
|
dielectric strength |
2 kV AC 50 Hz (shock wave 4 kV)
|
Unit Type of Package 1 |
PCE
|
|
---|---|---|
Number of Units in Package 1 |
1
|
|
Package 1 Weight |
123 g
|
|
Package 1 Height |
8 cm
|
|
Package 1 width |
4.6 cm
|
|
Package 1 Length |
9.7 cm
|
|
Unit Type of Package 2 |
S03
|
|
Number of Units in Package 2 |
48
|
|
Package 2 Weight |
6.526 kg
|
|
Package 2 Height |
30 cm
|
|
Package 2 width |
30 cm
|
|
Package 2 Length |
40 cm
|
Sustainable offer status |
Green Premium product
|
---|